IL5000 WIRELESS RESEARCH RADIOMETER
"The ILT1700 for the 21st Century"
Improvements on the ILT1700 (IL1700) include rapid measurements (1-100hz), broader dynamic range (100fA to 1mA), extensive supporting software apps, and built-in wireless, data storage, rechargeable batteries! Plus ALL IL/ILT1700 Detectors, Filters, Optics Are Compatible with ILT5000!
- 10 Decade Dynamic Range of Optical Analysis
- Also Highly Sensitive, Accurate Picoammeter
- Made in USA
- Wireless transmitter, built-in
* Order ILT5000A for Non-Wireless Version - Backwards Compatible with ILT1700 (IL1700) SED Detectors, Filters & Optics
- Autorange, Autodark, Auto-sample with User Control Options
- 4-20 mA output
- “Set it & Forget It” Remote Data Logging
- Built-in Re-Chargeable Battery Pack
- Multi-System Simultaneous Continuous Monitoring
- DataLight II Complementary Light Measurement and Data Collection Software Apps
- Labview Compatible
- NIST-Traceable/ISO17025 Accredited Calibration and Certificate
- Sample Rate Up to 100 Hz, Programmable
- Custom & OEM Inquiries Welcome
|
ILT5000 Meter Readout on PC/Tablet Screen
ILT5000 Trend Analysis on PC/Tablet Screen
ILT5000 DataLight
iMeter
|
TECHNICAL SPECIFICATIONS
Meter: - Measurement Range: 100 fA – 1 mA
- Reverse Bias: (2 Voltages/selectable)
- Automatic Ranging: Rapid switching through all current levels
- WiFi: Enabled
- Operating Temperature: -40 to 85°C (Calibrated Irradiance 0-40°C)
- USB: USB2, Including Power, for Single and Multiple Systems
- USB Current Draw: 500 mA max, 250 mA typical
- Size: 1-3/5” H x 5” W x 7” L
- Input connector: D-Sub and/or SMA.
- CE certified: No rf/noise
Software:
- CLI: Command line interface sent over a serial port
- Trigger: TTL, for synchronization of measurement**
- Data Storage: Internal (includes units, date and time stamps)
- Time Line: Scheduled data acquisition
- Integration Range: Unlimited dosage/exposure
- Transmission/Reflectance: (100%)
- Optical Density: 0.00 to 4.00
- Zero: (Dark or ambient subtraction)
- Direct Reading: Current or calibrated optical units
- Apps: Meters, CLI, Bar, Trend and Reports apps all included
** Coming soon: TTL trigger |
ILT5000 Research Radiometer with Optional Optics (Tablet and Optics sold separately)
Minimum Computer System Requirements: - Tablet: Minimum 8" tablet
- Operating System: Windows 7 or 8
- Memory/RAM: Minium 1 GB RAM (on board)
- Storage: 32GB (flash or SSD)
- Processor: at least 1.83GHz (with minimum 2MB Cache)
- Ports: 1 Micro-USB 2.0 Port
- Wi-Fi® Wireless networking (802.11b/g/n)
- Bluetooth® v 4.0
Also Recommended:
- Micro SD/SDHC/SDXC Card slot (for extra storage, data offloading/backup)
- OTG Cable (Micro-USB 2.0 to USB 2.0; for applying program updates as needed)
- Micro-USB to Ethernet Cable for Non-wireless Network Connectivity, if desired)
|
DataLight II Software
The ILT5000 comes with a complementary Labview DLL sample code, an extensive API and ILT’s DataLight II light measurement and data collection software. METERS - Designed to maintain the look and feel of the Industry Standard ILT1700 Research Radiometer. Designed for wireless use with windows 8 tablets and touch screen computers, the larger, user-friendly panel includes buttons for hold, zero, integrate, factor, range, average and units selection. TREND - Records all 6 parameters while displaying the trend over time for the user switchable parameter. Multiple examples of trend can be run simultaneously to allow multi-unit comparisons. Trend also has a user-friendly calibration feature. BAR - Allows multisystem, datalogging and displays the user switchable parameter in a bar graph. The expandable graph can accommodate up to 32 systems simultaneously with use of hub(s). User can enter nicknames for each unit to define the location, application, version, serial number, etc. Customer can program max and min warning levels and use color coded bar responses for easy troubleshooting. CLI is a very basic command line interface program that allows customer to type commands from the API and record readings into the device memory.
Datalog is a user interface that allows remote ”set it and forget it” datalogging.
IL1700 RESEARCH RADIOMETER
|
- 0.1 Percent
Linearity
- 40 Decade
Integration Range
- Light
Integration up to 18 Years
- 10
Calibration Factors in Memory
- Direct
Reading in any Units
- Remote
Control of Functions
- Darkroom Hold
Reading Feature
- Selectable
Reverse Bias (0 or 5 V)
- 115/230 VAC,
8-15 VDC, Battery Power
- Built-In
NiCad Battery Recharger
- Analog
Recorder Output (0-1 volt)
- RS232C and
TTL Digital Outputs
- Automatic
Zeroing
- Automatic 100
Percent
- Automatic
Ranging (On/Off)
|
FRONT PANEL
CONTROLS
REAR
PANEL The 'ZERO'
button nulls the ambient signal to zero. The 'D.C.'
button selects direct measurement mode. The 'INT'
button selects light dose integration mode. The 'HOLD'
button freezes the display and sends data to the optional printer.
The 'AUTO
RANGE' button selects either automatic or fixed range. The 'AUTO
100%' button sets the displayed signal to 100 percent.
The '5 V BIAS'
button provides an additional 5 volt reverse bias for flash integrations and for
all vacuum photodiode detectors.
The
'DATA/FACTOR DISPLAY' button selects either detector output or sensitivity
factor display.
The 'FACTOR
SELECT' button increments through the 10 sensitivity factor memory registers.
The 'MSD',
'LSD' and 'EXP' buttons allow the user to adjust the sensitivity factor.
The 'POWER'
button turns the power on/off.
An AUTO
SHUT-OFF feature automatically turns off the instrument if idle for more than 10
minutes in battery mode.
'BAT' and 'AC'
LED's indicate the power source, with low battery warning.
The 'CHG' LED
indicates batteries recharging. The 'OUTPUT
RECORDER/TTL' port allows simultaneous autoranging analog recorder output (0-1
volt) and TTL digital data (0-5 volts).
The 'AC
VOLTAGE' switch selects 115 or 230 VAC.
The
'COMPUTER/PRINTER' switch configures the standard 'RS232C DIGITAL OUTPUT'
connector to match DTE or DCE equipment.
The 'SOURCE
AC/BAT' switch selects AC or battery power.
The
'90-130/180-240 VAC' power input plug accepts the provided AC power cable.
The detector
cable plugs into the 'SENSOR INPUT', which also provides voltages of +15 V, 5 V,
and -9 V for various sensor probes.
The 24 line,
card edge connector labeled 'ACCESSORY INPUT' allows various input/output
functions: auxiliary power input, recorder output, RAM voltage check for
constant memory, and remote operation of 'ZERO', 'D.C.', 'INT', and 'HOLD'
functions.
ELECTRICAL / MECHANICAL:
Dynamic
Range: 2 x 10-13 to 2 x 10-3 A. Min.
Resolution: 0.01 x 10-11 Amperes. Linearity: ±0.1%, top
8 decades; ±0.2%, ±1 digit, bottom 2 decades. Display: 3 1/2 digit + 1
1/2 digit exp. Display Range: 1.000 x 10-19 to 9.99 x
10+19 display units. Input Impedance: Virtual Ground
(op-amp summing node). AC Power: 90-130 / 180-240 V, 50-400
Hz. DC Power: 8-15 V external, or 6 internal 'C' cells. Max
Power: 11 Watts. RS232C Output: DTE or DCE, ± 8 V. TTL
Output: 0 to 5 V. Recorder Output: 408 Ω impedance, 100 to 1000
mV, ranging every decade, current limited. Size: 90 mm x 220 mm x 240
mm (3.5" x 8.7" x 9.4"). Weight: 2.3 kg (5.1 lbs.).
광량계,
IL1700, IL1400, uv curing, radiometer, 경화, 자외선,
적외선, 근적외선, 원적외선, 가시광선, 건조, 화학방사선,
세정, 살균, 수처리, 태양광, 복사량측정, 광량계, 조도계,
광도계, 센서, 스펙트로메타, 라디오메타, 포토메타, 스펙트로라디오메타,
uv, LED, 자외선측정, UV광량, IL393, IL290, LZ393, IL393,
ILT400, ILT490, ILT1700, ILT1400, ILT900, ILT900 LED,
색차계,조사, 분광, 스펙트럼, 분석, 복사도, 환경, 생화학,
광생물학, 레이저,
ultraviolet
radiation, uv meter, light bugs, UVA, UV-b, UV-A, UVB,
UVC, UV-Cil290a, il390c, il393, uv exposure,
노광,
spot irradiance measurements, il1747, il1447, il1745,
il1445, pir irradiance calibration,
photometry,
photometer system, photometric illuminance, flash photometer,
radiometer, high gain lens, flash sources, flash effective
intensity, il1710, il1410, il1711, il1715, radiometer,
visible, near-ir, irradiance measurements, radiometry,
spatial response, uv detection, radiance measurements,
irradiance detector, nist traceable, il1705, il1405,
il1715, photometer system, photoresist, a response,
b response, uv measurement, blue visible irradiance,
exposing photoresist, uva, photoresist equipment, radiometer,
uv sensitivity, il1740a
|
|