DTX logo

 

Thinking Advanced Technologies !!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

  광계측기기 (OPTICAL INSTRUMENTS)

 

 

  Home > Instrument > 광계측기기  

 

 

     

 

 

ILT 950 / 950UV PORTABLE SPECTRORADIOMETER

 

Most Cost-Effective, Fully Integrated, CCD-based Spectroradiometer Family Available with ISO17025 Accredited Calibration

 

  • Two Spectroradiometer Versions:
    • ILT950: 250-1050 nm
    • ILT950UV: 200-450 nm
  • NIST-Traceable, ISO 17025 Accredited Calibration Included
  • Typical spectroradiometer applications include:
    • Plant Growth/PAR/Plant Photobiology
    • Characterization of Solar Simulation
    • Characterization of UV Curing Systems
    • Photostability Testing
    • Accelerated Weathering
    • Radiometery and Photometry Measurements
    • LED Illumination and Color Analysis
    • Absorbance/Transmittance
    • Reflectance
    • Fluorescence

자외선 가시광선 SPECTRORADIOMETER (ILT950) - 디티엑스 

ILT950UV Spectroradiometer - 200-450 nm (calibration options: single source 200-350 nm or dual cal 200-450 nm)

ILT950 Spectroradiometer - 200-1100 nm (calibration options: single source 350-1050 nm or dual cal 250-1050 nm) ) 

 

Specifications

 

Two Versions:

Data Transfer Speed: 2ms/scan

  • ILT950: 250-1050 nm

16 bits, 2 MHz

    Resolution: 1.4 nm with 25 micron slit**

Trigger Compatible

  • ILT950UV: 200-450 nm

Synchronization Capability

    Resolution: >1 nm with 50 micron slit**

Temperature Range: 15 - 40°C

NIST-Traceable/ISO17025 Accredited Calibration**

Size: 1-3/5” H x 5” W x 7” L

CCD Array: 2048 Pixel Sony

Dynamic Dark Correction: Yes

Focal Length: 75 mm

Non-Linearity Calibration: Yes

Blaze

Wavelength Accuracy: ±.5 nm

Dynamic Range: 3300

Radiometric Accuracy:

Symmetrical Czerny-Turner

  • 200nm - 350nm: ±20%**

Stray light: <0.3%

  • >350nm - 400 nm: ±10%**

Signal/Noise: 300:1

  • >400nm - 900nm: ±5%

Integration Time: 2µs ~ 20s

  • >900nm - 1050nm: ±10%

 

 

** (Note: Dual range calibration with D2 and QTH light source is strongly recommended for broadband measurements encompassing UV below 350 nm due to low output of the QTH lamp which increases the difficulty of accurate UV calibration. The ILT950 can be calibrated with QTH light source only if UVB/C accuracy is not consequential.)

 

The ILT950 Spectroradiometer comes standard in two standard ranges, ILT950 250-1050 nm and the ILT950UV 200-450 nm.

To make ordering easy, ILT offers pre-configured complete measurement systems which include everything you will need to take accurate, calibrated light measurements.

 

  • ILT950 Remote Optic Irradiance Spectroradiometer System includes the ILT950 spectroradiometer, FFOSMA2UV1000 2 meter long fiber optic, W2 wide eye diffuser, single source calibration from 250-1050 nm, SpectrILight III software, Tripod and carrying case. (For UV use: ILT950UV version with W diffuser and dual source cal 200-450 nm)
  • ILT950CR Clean room “NO UV” Spectroradiometer Verification System includes the ILT950 spectroradiometer, WD direct mount diffuser, Short pass 500 nm filter, Dual source calibration from 250-500 nm, SpectrILight III software and carrying case. Used to verify the UV blocking filters use in clean room environments..
  • ILT950RAA Colorimetry/Right Angle Irradiance Spectroradiometer System includes the ILT950 spectroradiometer, SC600 600 um fiber optic light guide with RAA4 right angle diffuser, Single source calibration from 250-1050 nm, SpectrILight III software and carrying case. With the new enhances colorimetry features such as Metamerism calculation this is an excellent configuration designed for testing lamp output in light booths used in the graphic arts industry. (For UV use: ILT950UV version with RAA4 diffuser and dual source cal 200-450 nm)
  • ILT950P Power/Flux Measurement Spectroradiometer System includes the ILT950 spectroradiometer, FFOSMA2UV1000 2 meter long armored fiber optic, INS125 5” integrating sphere, Single source calibration in Watts/Lumens from 250-1050 nm, SpectrILight III software, Tripod and carrying case. For total flux measurements of LED's and many other types of miniature lamps. (For UV use: ILT950UV version with INS125 integrating sphere and dual source cal 200-450 nm)
  • ILT950R Luminance/Radiance Spectroradiometer Measurement System includes the ILT950 spectroradiometer, FF0600SC 600 micron 1 meter long fiber optic, R3 Spot luminance optic, A706 light source, Single source calibration for radiance/lumiance from 250-1050 nm, SpectrILight III software, Tripod and carrying case. (Not recommended for dual source cal/UV measurements)

 

Prefer to configure your own light measurement system?

 

The ILT950B and ILT950UV/B base spectroradiometers allow customers to choose from our vast array of fibers, input optics, accessories, calibrations, and software, for total flux, irradiance, radiance, colorimetry, luminance and illuminance. Please click on the accessories link below to learn more. The ILT950 base units only include the spectrometer, carrying case and SpectrILight software (Fiber, input optic, calibration, certification,and tripod sold separately)

(DLL's for SpectrILight III are sold separately)

 

 

 

Optional Accessories

 

10-inch integrating sphere  R2 Radiance Optic for use with ILT spectroradiometer systems with additional calibration R3 Spot Radiance Optic for use with ILT spectroradiometer systems with additional calibration Spot Finder 5-inch Integrating Sphere for use with ILT radiometers and spectroradiometers 

 

  • Three integrating spheres; 2, 5 and 10 inch
  • Two luminance optics; spot luminance and +/- 2 Deg FOV
  • Three versions of cosine receptors; mini, standard, right angle
  • Four fiber optic cables; bundled 2 m L, 600 um 1 m long, 200 um .5 m Long, Bifurcated
  • Validation lamp and power supply for integrating spheres, reference measurements
  • Reflectance reference - white
  • Spot finding light source for luminance optics
  • Optical Bench post
  • SpectrILight III Software 

 

 

 

SpectrILight III Software

SpectriLight III Software

SpectrILight™ III is a LabView™ based software package for Windows that allows you to acquire spectral and color data. Analysis of the data is now calculated instantly within the same program - no exporting required!

 

The NEW version of SpectrILight™ III has additional calculations for metamerism, and 2 and 20 degree observer. The new Overlay feture allows the user to compare the base reading to current radings. Wavelength range, integration time, scan average and other controls can be easily set through pop up windows, menus and tool bars. Absolute Irradiance and chromaticity are calculated instantly.

 

SpectrILight™ III is LabView™ based software and can be easily customized for specific OEM applications. For API applications, Multiple DLL’s are available. Please contact ILT Technical Sales for more information.

 

To learn more about SpectrILight software, please click on the following Technical Information links below: SpectriLight III Spectral Analysis Software Datasheet and SpectriLight III Spectral Analysis Software Manual.

 

Requires Windows XP Pro or Windows 7 Pro Editions (Pentium II 300 MHz or better). Note: Software will not work with Windows "Home" editions.

 

 

광량계, IL1700, IL1400, uv curing, radiometer, 경화, 자외선, 적외선, 근적외선, 원적외선, 가시광선, 건조, 화학방사선, 세정, 살균, 수처리, 태양광, 복사량측정, 광량계, 조도계, 광도계, 센서, 스펙트로메타, 라디오메타, 포토메타, 스펙트로라디오메타, uv, LED, 자외선측정, UV광량, IL393, IL290, LZ393, IL393, ILT400, ILT490, ILT1700, ILT1400, ILT900, ILT900 LED, 색차계,조사, 분광, 스펙트럼, 분석, 복사도, 환경, 생화학, 광생물학, 레이저,

ultraviolet radiation, uv meter, light bugs, UVA, UV-b, UV-A, UVB, UVC, UV-Cil290a, il390c, il393, uv exposure,

노광, spot irradiance measurements, il1747, il1447, il1745, il1445, pir irradiance calibration,

photometry, photometer system, photometric illuminance, flash photometer, radiometer, high gain lens, flash sources, flash effective intensity, il1710, il1410, il1711, il1715, radiometer, visible, near-ir, irradiance measurements, radiometry, spatial response, uv detection, radiance measurements, irradiance detector, nist traceable, il1705, il1405, il1715, photometer system, photoresist, a response, b response, uv measurement, blue visible irradiance, exposing photoresist, uva, photoresist equipment, radiometer, uv sensitivity, il1740a

 

 

 

Top of Page

 

 

 

DTX logo

경기도 시흥시 정왕천로 197, A-512 (정왕동  동우디지털파크)   |  E-mail : contact@dtx.co.kr  

Tel : 031-497-1134 (代)   |  Fax : 031-497-1138   |   Internet Fax : 0505-497-7710

 All Rights Reserved, Copyright (C) DTX, INC. 2008   

 

 

FEATURED PRODUCTS

 

 

◎  UV CURING SYSTEM

   ◎   INFRARED DRYING SYSTEM

   ◎  PULSE UV SYSTEM

◎  OPTICAL INSTRUMENTS

   ◎   PHOTONIC SINTERING SYSTEM

   ◎  X-UV SYSTEM

◎  SOLAR SIMULATION SYSTEM

   ◎   WEATHER / FADE TESTING SYSTEM

   ◎  PULSE UV STERILIZATION SYSTEM

◎  XENON IRRADIATION SYSTEM

   ◎   ENGINEERING

   ◎  INSPECTION SYSTEM

◎  LIGHT SOURCE

   ◎   PHOTONIC ACTIVATION SYSTEM